Rotenso Aquami AQM60X1 Heat Pump 6kW Monoblock 1PH Outdoor unit

Login to See Price
0 pcs
Availability:
24h Bialystok
0 pcs
72h Central
0 pcs
SKU
1897
Rotenso Aquami AQM60X1 Heat Pump 6kW Monoblock 1PH Outdoor unit is available to buy in increments of 1

Rotenso Aquami Monoblock 1F 6KW heat pump AQM60X1 R13 (outdoor unit)

The Rotenso Aquami Monoblock is a heat pump in which the cooling module and the hydraulic module are contained in a single, compact unit housing.
This makes it easier and quicker to install the pump. It also does not require additional space for the hydraulic module inside the building.

The two-door design of the pump casing ensures easy access to all its components, and the user interface ensures simple and fast parameter change and real-time monitoring.

The modern design of Rotenso heat pumps and their high efficiency, even at low temperatures, make them ideal for heating homes, shops, commercial premises and offices.

Air monoblock heat pump
Both the refrigeration and hydraulic modules of the heat pump are placed in one casing. The unit is installed outside the building and directly connected to the building's heating circuit.

The advantages of the monoblock solution are:

  • it takes up no space inside the building
  • possibility to locate the pump further away from the building (more than 15m)
  • does not require the installer to be qualified to work with refrigerants (F-gas)


Energy efficiency level: A+++ (35°C)
Rotenso Aquami Monoblock heat pumps have the highest energy efficiency class A+++ (for a water temperature of 35°C).
This excellent performance significantly contributes to low electricity consumption.

Wired controller with integrated Wifi module
You control - He will do.
The Rotenso Aquami Monoblock offers the possibility to control the pump both from the wired controller and from the COMFORT HOME mobile app. Whether you are in or out of the house.

Single-Fan Design, High Efficiency, Quiet Operation
The pump's single-fan design, bionic fan blade pattern, two-rotary DC compressor and new piping design provide the Rotenso Aquami's high efficiency with minimal sound power - only 35 dB (A) (level 2 in quiet mode).

Maximum flow water temperature is 65°C
When you use a heat pump for space heating with radiators, it is necessary to be able to prepare water to supply the system at a higher temperature.
Rotenso Aquami pumps are capable of preparing waterat temperatures as low as 65°C

Realisation of the heating function at -25°C
The pumps are prepared for efficient operation even at extreme outdoor temperatures down to -25°C.
During cold winters, they guarantee the preparation of hot water for central heating and DHW supply.

Maximum COP5.15
The COP parameter is the ratio of the obtained heating power to the consumed electricity. It defines the heating efficiency of a heat pump.
Aquami pumps can produce more than five times the heating energy in relation to the electricity consumed.

5-year warranty
All heat pumps are covered by a full 5-year warranty. The high quality workmanship will allow you to enjoy the reliability of your pump for many years.

The unit includes:

  • external unit
  • wired controller
  • DHW tank sensor
  • plate heat exchanger
  • flow sensor,
  • diaphragm vessel
  • pressure gauge
  • water pump,
  • safety valve,
  • vent valve,
  • Y-type water filter

Characteristics:

  • Rated heating power: 6 / 8 / 10 / 12 / 14 / 16 kW
  • Energy class: A++ (for 35°C) / A++ (for 55°C)
  • COP: up to 5.15
  • Operation in extreme conditions down to - 25°C
  • Max water temperature in heating mode: 65°C
  • Max. water temperature in DHW mode: 60°C
  • Independent control of two heating circuits
  • Flexible electric heater output of 9kW (3+3+3)
  • Drip tray and compressor crankcase heater
  • Certification: SG Ready
  • Warranty: 5 years
Specification - AQM60X1:
  • Power supply: (V-Hz, Ø)220-240~50, 1f
  • Heating (A7/W35) \Performance (kW): 6.35
  • Heating (A7/W35) \nPower consumption (kW): 1.28
  • Heating (A7/W35) \nCOP: 4.95
  • Heating (A7/W45) \nEfficiency (kW): 6.3
  • Heating (A7/W45) \nPower consumption (kW): 1.7
  • Heating (A7/W45) _COP: 3.7
  • Heating (A7/W55) \nPower output (kW): 6
  • Heating (A7/W55) \nPower consumption (kW): 2.03
  • Heating (A7/W55) _COP: 2.95
  • Cooling (A35/W18) \Power output (kW): 6.5
  • Cooling (A35/W18) \nPower consumption (kW): 1.35
  • Cooling (A35/W18) ER: 4.8
  • Cooling (A35/W7) \nEfficiency (kW): 7
  • Cooling (A35/W7) \nPower consumption (kW): 2,33
  • Cooling (A35/W7) - EER: 3
  • Seasonal energy efficiency TWW at 35°C \n SCOP (1): 4.95
  • Seasonal energy efficiency TWW at 35°C \n Seasonal energy efficiency ratio (ηS) (%): 195
  • Seasonal energy efficiency TWW at 35°C \nAnnual energy consumption (kWh): 2.845
  • Seasonal energy efficiency TWW at 35°C \n Seasonal energy efficiency class for space heating (1): A+++
  • Seasonal energy efficiency TWW at 55°C \n SCOP (1): 3.52
  • Seasonal energy efficiency TWW at 55°C \n Rated heating output (kW): 5.7
  • Seasonal energy efficiency TWW at 55°C \n Seasonal energy efficiency ratio (ηS): 137.9
  • Seasonal energy efficiency TWW at 55°C / Annual energy consumption (kWh): 3.343
  • Seasonal energy efficiency TWW at 55°C / Seasonal energy efficiency class for space heating (1)A++
  • SEER \W at 7°C: 5.34
  • SEER ■ TWW at 18°C: 8.21
  • Maximum drive protection (MZN) (A): 31
  • Minimum circuit overload (MOO) (A): 27
  • Compressor Type: Two-rotary DC compressor
  • Fan Type: Brushless DC
  • Fan \n-Number: 1
  • Refrigerant Type: R32
  • Refrigerant GWP: 675
  • Refrigerant \nQuantity (up to 15 mb) (kg): 1.4
  • Refrigerant \nQuantity (up to 15 mb) (TCO2eq): 0.95
  • Supply lines: outdoor unit (qty. × mm²): 3 × 6
  • Fixing spacing (SxG) (mm): 760 x 397
  • Sound pressure level (dB(A)): 47.5
  • Sound power level (dB(A)): 58
  • Net dimensions (SxWxG) (mm): 1295×429×792
  • Gross dimensions (SxWxG) (mm): 1385×526×945
  • Net weight / Gross weight (kg): 103/126
  • Outdoor operating range Cooling (⁰C):-5~43
  • Outdoor operating range ⁰C Heating (⁰C): -25~35
  • Outdoor operating range ⁰C DHW (⁰C): -25~43
  • Operating mode: Heating and cooling
  • Outlet water temperature ⁰C space cooling (°C): 5~25
  • Outlet water temperature \ Space heating (°C): 25~65
  • DHW outlet water temperature (°C): 40~60
  • Electric heater \nPower supply (V-Hz, Ø): 220-240~50, 1f
  • Electric heater \n-Number of heating stages (pcs.): 1
  • Electric heater \nWattage (kW): 3
  • Electric heater \ Maximum operating current (A): 13.5
  • Water circuit \nWater connections (mm(inch)): 33mm (G1" BSP) external
  • Water circuit \nSafety valve pressure (MPa): 0.3
  • Water circuit \nDroplet outlet (mm): 16
  • Water circuit ■ Expansion vessel ■ Capacity (l): 8
  • Water circuit ■ Expansion vessel ■ Maximum pressure (MPa): 0.3
  • Water circuit - expansion vessel - pre-pressure: 0.1
  • Heat exchanger Type: plate heat exchanger
  • Water circuit \nHeat exchanger \nMinimum flow rate (l/min): 6
  • Water circuit \ Water pump head (m): 9
  • Water circuit \NWater pump type: DC
  • Water circulation \ Total water volume (l): 3.2
More Information
EAN5905567602184
ManufacturerRotenso
Weight126.000000
Warranty5
Power kW6.00 kW
Number of Phase1-phase
RefrigerantsR32
ColourWhite