Zineric ZIN-BOX Solar Distribution Box DC+AC 3-5kW 1String 3PH SPD T2 - B10 SPD T2

Zineric ZIN-BOX Solar Distribution Box DC+AC 3-5kW 1String 3PH SPD T2 - B10 SPD T2 is available to buy in increments of 1
The boxes are designed for use in photovoltaic installations with or without insulated lightning protection, also where a high IP degree of protection is required. Their design is suitable for surface mounting.

The price includes a complete AC/DC box for self-assembly:
  • 1 x module chain for 1 mppt
  • 1 x DC surge arrester type 2
  • 1 x type 2 AC surge arrester
  • 1 x 3-phase overcurrent circuit breaker 10A
  • Ready to connect
  • Modular version
  • MC4 board connections
  • Degree of protection IP65
  • Transparent door
  • Protection class II
  • Colour: white
ELECTRICAL AND MECHANICAL SPECIFICATIONS OF THE ENCLOSURE
  • Model PHS 12T
  • Number of modules 12
  • Design in compliance with EN 60670-1, EN 62208
  • Degree of protection IP65
  • Protection class II
  • Rated insulation voltage (Ui) 690 V AC, 1000 V DC
  • 650°C glow rod test
  • Impact resistance IK08
  • Halogen-free recyclable plastic
DC SURGE ARRESTER USED
  • Manufacturer/model PHOENIX/VAL-MS 1000DC-PV/2+V
  • Surge protection Type 2
  • Maximum permanent voltage UCPV 1170 V DC
  • Short-circuit immunity I SCPV 2000 A
  • Long-term operating current ICPV <20 uA
  • Rated load current IL 80 A
  • Protective conductor current IPE <=20 uA DC
  • <=250 uA AC
  • Standby power consumption PC <=25 mVA
  • Rated discharge current (8/20) us 15 kA
  • Max. discharge current Imax (8/20) us 40 kA
  • Total discharge current Itotal (8/20) us 40 kA
  • Protection level Up <= 3.7 kV
  • Residual voltage Ures <= 3.7 kV (at In)
  • <= 3,1 kV (at 5kA)
  • <= 3,5 kV (at 10kA)
  • <= 4 kV (at 20kA)
  • <= 4,6 kV (at 30kA)
  • <= 5 kV (at 40kA)
  • Response time tA <= 25ns
  • Insulation resistance Riso <= 5 Gigia OM (at 500 VDC)
  • *In case of low stock or lack of the right product, it is replaced by an equivalent product from the OBO manufacturer with the index 5094608
OVERCURRENT CIRCUIT BREAKER USED
  • Manufacturer/model Noark/Ex9BN 3P B10
  • Rated current 10A; 3-phase
  • Number of poles 3
  • Characteristic B
  • Version according to IEC/EN 60898-1
  • Rated short circuit breaking capacity ICN
More Information
ManufacturerZineric
Weight2.800000
Warranty5
Inverter Min Power3
Inverter Max Power5
VoltageAC+DC
Number of Phase3-phase
Circuit Protection1
SPD TypesT2
Width In Number Of Modular Spacings12.00
IP CodeIP65
Width16.00 cm
Height33.50 cm
Length/Depth30.50 cm
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
More from Zineric
Copyright © 1992-present ecoABM sp. z o.o. All rights reserved.