Zineric ZIN-BOX Solar Distribution Box AC DC 6-8kW 1String 3PH SPD T1T2 + B16 SPD T1T2

Zineric ZIN-BOX Solar Distribution Box AC DC 6-8kW 1String 3PH SPD T1T2 + B16 SPD T1T2 is available to buy in increments of 1

Complete Zineric DC+AC photovoltaic switchgear for self-assembly:

Characteristics:

  • 1 x module chain per 1 mppt
  • 1 x DC surge arrester type 1+2
  • 1 x type 1+2 AC surge arrester
  • 1 x 3-phase overcurrent circuit breaker 16A
  • MC4 board connections
  • Degree of protection IP65
  • Transparent door
  • Protection class: II
  • Colour: white

Distribution box suitable for photovoltaic systems in the power range 6-8kW

  • The boxes are designed for photovoltaic installations with or without lightning protection, also where a high IP degree of protection is required.
  • Their construction is suitable for surface mounting.

ELECTRICAL AND MECHANICAL CHARACTERISTICS OF THE HOUSING

  • Model PHS 12T
  • Number of modules 12
  • Version according to EN 60670-1, EN 62208
  • Degree of protection IP65
  • Protection class II
  • Rated insulation voltage (Ui) 690 V AC, 1000 V DC
  • 650°C glow rod test
  • Impact resistance IK08
  • Halogen-free recyclable plastic

USED OVERCURRENT CIRCUIT BREAKER B16 3F

  • Manufacturer/model Noark/Ex9BN 3P B16
  • Rated current 16A; 3-phase
  • Number of poles 3
  • Characteristic B
  • Version according to IEC/EN 60898-1
  • Rated short-circuit breaking capacity ICN 6kA

AC T1+T2 SURGE ARRESTER USED

  • Manufacturer/model Noark/Ex9UE1+2 12.5 3PN 275
  • Design in accordance with EN 61643-11
  • Arrester type Type 1+2 (Class I+II, B+C, T1+T2)
  • Insertion type L-N: MOV (varistor), N-PE: GDT (spark gap)
  • Endurance voltage Uc L-N: 275 V AC, N-PE: 255 V AC
  • Frequency f 50-60Hz
  • Rated discharge current In (8/20 us) L-N: 20 kA per pole, N-PE: 40 kA per pole
  • Max. impulse current limp (10/350 us) L-N: 12.5 kA per pole, N-PE: 50 kA per pole
  • Max. discharge current Imax (8/20 us) 50 kA per pole
  • Voltage protection level Up for current In L-N: 1,5 kV, N-PE: 1.5 kV
  • Voltage protection level Up for current Imax L-N: 1.8 kV, N-PE: 1.5 kV
  • Voltage protection level Up for 5 kA (8/20 us) L-N: 2 kV, N-PE: 1.5 kV
  • N-PR fault current suppression capability Ifi 100A
  • Surge surges Ut (withstand) L-N: 5s : 335 V, N-PE: 200 ms : 1200 V
  • Arrester voltage for 1 mA current 387 - 473 V
  • Maximum fuse protection L-N: max. 160 A gG, N-PE: -
  • Short-circuit current withstand capability L-N: 50 kA, N-PE: -

DC SURGE ARRESTER USED T1+T2

  • Manufacturer/model PHOENIX/VAL-MS-T1/T2 1000DC-PV/2+V
  • Surge protection Type 1+2
  • Maximum permanent voltage UCPV 1050 V DC
  • Short-circuit immunity I SCPV 2000 A
  • Long-term operating current ICPV <20 uA
  • Rated load current IL 80 A
  • Protective conductor current IPE <=20 uA DC <=250 uA AC
  • Standby power consumption PC <=25 mVA
  • Rated discharge current (8/20) us 15 kA
  • Max. discharge current Imax (8/20) us 40 kA
  • Collected lightning current (10/350) us, load 2.5 As
  • Collected lightning current (10/350) us, specific energy 6,25 kJ/OM
  • Dissipated lightning current (10/350) us, peak Limp 5 kA
  • Total dissipated current Itotal (8/20) us 40 kA
  • Total dissipated current Itotal (10/350) us 5 kA
  • Protection level Up <= 3.5 kV
  • Residual voltage Ures <= 3.5 kV (at In)
  • <= 2,9 kV (at 5kA)
  • <= 3,2 kV (at 10kA)
  • <= 3.7 kV (at 20kA)
  • <= 4,1 kV (at 30kA)
  • <= 4.6 kV (at 40kA)
  • Response time tA <= 25ns
  • Insulation resistance Riso <= 5 Gigia OM (at 500 VDC)
More Information
EAN 5906639360285
Manufacturer Zineric
Warranty 5
Inverter Min Power 6
Inverter Max Power 8
Voltage AC+DC
Number of Phase 3-phase
Circuit Protection 1
SPD Types T1+T2
Width In Number Of Modular Spacings 12.00
IP Code IP65