Zineric ZIN-BOX Solar Distribution Box AC DC 6-8kW 1String 3PH SPD T1T2 + B16 SPD T1T2
SKU
3273
Zineric ZIN-BOX Solar Distribution Box AC DC 6-8kW 1String 3PH SPD T1T2 + B16 SPD T1T2 is available to buy in increments of 1
Complete Zineric DC+AC photovoltaic switchgear for self-assembly:
Characteristics:
- 1 x module chain per 1 mppt
- 1 x DC surge arrester type 1+2
- 1 x type 1+2 AC surge arrester
- 1 x 3-phase overcurrent circuit breaker 16A
- MC4 board connections
- Degree of protection IP65
- Transparent door
- Protection class: II
- Colour: white
Distribution box suitable for photovoltaic systems in the power range 6-8kW
- The boxes are designed for photovoltaic installations with or without lightning protection, also where a high IP degree of protection is required.
- Their construction is suitable for surface mounting.
ELECTRICAL AND MECHANICAL CHARACTERISTICS OF THE HOUSING
- Model PHS 12T
- Number of modules 12
- Version according to EN 60670-1, EN 62208
- Degree of protection IP65
- Protection class II
- Rated insulation voltage (Ui) 690 V AC, 1000 V DC
- 650°C glow rod test
- Impact resistance IK08
- Halogen-free recyclable plastic
USED OVERCURRENT CIRCUIT BREAKER B16 3F
- Manufacturer/model Noark/Ex9BN 3P B16
- Rated current 16A; 3-phase
- Number of poles 3
- Characteristic B
- Version according to IEC/EN 60898-1
- Rated short-circuit breaking capacity ICN 6kA
AC T1+T2 SURGE ARRESTER USED
- Manufacturer/model Noark/Ex9UE1+2 12.5 3PN 275
- Design in accordance with EN 61643-11
- Arrester type Type 1+2 (Class I+II, B+C, T1+T2)
- Insertion type L-N: MOV (varistor), N-PE: GDT (spark gap)
- Endurance voltage Uc L-N: 275 V AC, N-PE: 255 V AC
- Frequency f 50-60Hz
- Rated discharge current In (8/20 us) L-N: 20 kA per pole, N-PE: 40 kA per pole
- Max. impulse current limp (10/350 us) L-N: 12.5 kA per pole, N-PE: 50 kA per pole
- Max. discharge current Imax (8/20 us) 50 kA per pole
- Voltage protection level Up for current In L-N: 1,5 kV, N-PE: 1.5 kV
- Voltage protection level Up for current Imax L-N: 1.8 kV, N-PE: 1.5 kV
- Voltage protection level Up for 5 kA (8/20 us) L-N: 2 kV, N-PE: 1.5 kV
- N-PR fault current suppression capability Ifi 100A
- Surge surges Ut (withstand) L-N: 5s : 335 V, N-PE: 200 ms : 1200 V
- Arrester voltage for 1 mA current 387 - 473 V
- Maximum fuse protection L-N: max. 160 A gG, N-PE: -
- Short-circuit current withstand capability L-N: 50 kA, N-PE: -
DC SURGE ARRESTER USED T1+T2
- Manufacturer/model PHOENIX/VAL-MS-T1/T2 1000DC-PV/2+V
- Surge protection Type 1+2
- Maximum permanent voltage UCPV 1050 V DC
- Short-circuit immunity I SCPV 2000 A
- Long-term operating current ICPV <20 uA
- Rated load current IL 80 A
- Protective conductor current IPE <=20 uA DC <=250 uA AC
- Standby power consumption PC <=25 mVA
- Rated discharge current (8/20) us 15 kA
- Max. discharge current Imax (8/20) us 40 kA
- Collected lightning current (10/350) us, load 2.5 As
- Collected lightning current (10/350) us, specific energy 6,25 kJ/OM
- Dissipated lightning current (10/350) us, peak Limp 5 kA
- Total dissipated current Itotal (8/20) us 40 kA
- Total dissipated current Itotal (10/350) us 5 kA
- Protection level Up <= 3.5 kV
- Residual voltage Ures <= 3.5 kV (at In)
- <= 2,9 kV (at 5kA)
- <= 3,2 kV (at 10kA)
- <= 3.7 kV (at 20kA)
- <= 4,1 kV (at 30kA)
- <= 4.6 kV (at 40kA)
- Response time tA <= 25ns
- Insulation resistance Riso <= 5 Gigia OM (at 500 VDC)
EAN | 5906639360285 |
---|---|
Manufacturer | Zineric |
Warranty | 5 |
Inverter Min Power | 6 |
Inverter Max Power | 8 |
Voltage | AC+DC |
Number of Phase | 3-phase |
Circuit Protection | 1 |
SPD Types | T1+T2 |
Width In Number Of Modular Spacings | 12.00 |
IP Code | IP65 |