Zineric ZIN-BOX Solar Distribution Box AC 3-5kW 3PH B10 SPD T2

Login to See Price
49 pcs
Availability:
24h Bialystok
2 pcs
72h Central
47 pcs
SKU
3267
Zineric ZIN-BOX Solar Distribution Box AC 3-5kW 3PH B10 SPD T2 is available to buy in increments of 1

Complete Zineric Photovoltaic AC Switchgear for self-assembly:

Characteristics:

  • 1 x type 2 AC surge arrester
  • 1 x 3-phase overcurrent circuit breaker 10A
  • Ready to connect.
  • Modular design
  • Degree of protection IP65
  • Transparent door
  • Protection class II
  • Colour: white

Distribution box suitable for photovoltaic systems in the power range 3-5kW

The boxes are designed for photovoltaic installations with or without lightning protection, also where a high IP degree of protection is required. Their design is suitable for surface mounting.

Attention:

For ease of product navigation, it has been suggested to select the modular apparatus on the AC side under the inverter power and on the DC side under the number of MPPTs.

However, in order to select the correct switchgear, the inverter's data sheet should be read in detail and the appropriate Zineric switchgear should be selected by a qualified electrician.

ELECTRICAL AND MECHANICAL PARAMETERS OF THE CABINET

  • Model PHS 8T
  • Number of modules 8
  • Design in compliance with EN 60670-1, EN 62208
  • Degree of protection IP65
  • Protection class II
  • Rated insulation voltage (Ui) 690 V AC, 1000 V DC
  • 650°C glow rod test
  • Impact resistance IK08
  • Halogen-free recyclable plastic

AC T2 SURGE ARRESTER USED

  • Manufacturer/model Noark/Ex9UE2 12.5 3PN 275
  • Design in accordance with EN 61643-11
  • Arrester type Type 2 (Class II, C, T2)
  • Insertion type L-N: MOV (varistor), N-PE: GDT (spark gap)
  • Endurance voltage Uc L-N: 275 V AC, N-PE: 255 V AC
  • Frequency f 50-60Hz
  • Rated discharge current In (8/20 us) L-N: 20 kA per pole, N-PE: 40 kA per pole
  • Max. Impulse current limp (10/350 us) N-PE: 12 kA per pole
  • Max. Discharge current Imax (8/20 us) 40 kA per pole
  • Voltage protection level Up for current In L-N: 1.4 kV, N-PE: 1.5 kV
  • Voltage protection level Up for current Imax L-N: 2 kV, N-PE: 1.5 kV
  • Voltage protection level Up for 5 kA (8/20 us) L-N: 2 kV, N-PE: 1.5 kV
  • N-PR fault current suppression capability Ifi 100A
  • Surge surges Ut (withstand) L-N: 5s : 335 V, N-PE: 200 ms : 1200 V
  • Arrester voltage for 1 mA current 387 - 473 V
  • Maximum fuse protection L-N: max. 125 A gG, N-PE: -
  • Short-circuit current withstand capability L-N: 50 kA, N-PE: -

USED OVERCURRENT CIRCUIT BREAKER B10 3F

  • Manufacturer/model Noark/Ex9BN 3P B20
  • Rated current 10A; 3-phase
  • Number of poles 3
  • Characteristic B
  • Version according to IEC/EN 60898-1
  • Rated short circuit breaking capacity ICN 6kA
More Information
EAN5906639360209
ManufacturerZineric
Warranty5
Inverter Min Power3
Inverter Max Power5
VoltageAC
Number of Phase3-phase
SPD TypesT2
Width In Number Of Modular Spacings8.00
IP CodeIP65
ColourWhite