Zineric ZIN-BOX Solar Distribution Box AC DC 9-10kW 2String 3PH SPD T1T2 + B20 SPD T1T2

Login to See Price
59 pcs
Availability:
24h Bialystok
1 pcs
72h Central
58 pcs
SKU
3274
Zineric ZIN-BOX Solar Distribution Box AC DC 9-10kW 2String 3PH SPD T1T2 + B20 SPD T1T2 is available to buy in increments of 1

Complete Zineric DC+AC photovoltaic switchgear for self-assembly:

Characteristics:

  • 2 x module chain for 2 mppt
  • 2 x DC surge arrester type T1+T2
  • 1 x T1+T2 type AC surge arrester
  • 1 x 3-phase overcurrent circuit breaker 20A
  • Ready to connect.
  • Modular version
  • MC4 board connections
  • Degree of protection IP65
  • Transparent door
  • Protection class II
  • Colour: white

Distribution box suitable for photovoltaic systems in the power range 9-10kW

The boxes are designed for photovoltaic installations with or without lightning protection, also where a high IP degree of protection is required.

Their design is suitable for surface mounting.

*Note:

For ease of product navigation, the selection of AC-side modular apparatus under the inverter power is suggested.

However, in order to select the correct switchgear, the inverter data sheet should be consulted carefully and the appropriate Zineric switchgear should be selected by a qualified electrician.

ELECTRICAL AND MECHANICAL SPECIFICATIONS OF THE ENCLOSURE

  • Model PHS 24T
  • Number of modules 24
  • Design in accordance with EN 60670-1, EN 62208
  • Degree of protection IP65
  • Protection class II
  • Rated insulation voltage (Ui) 690 V AC, 1000 V DC
  • 650°C glow rod test
  • Impact resistance IK08
  • Halogen-free recyclable plastic

USED OVERCURRENT CIRCUIT BREAKER B20 3F

  • Manufacturer/model Noark/Ex9BN 3P B20
  • Rated current 20A; 3-phase
  • Number of poles 3
  • Characteristic B
  • Version according to IEC/EN 60898-1
  • Rated short-circuit breaking capacity ICN 6kA

AC T1+T2 SURGE ARRESTER USED

  • Manufacturer/model Noark/Ex9UE1+2 12.5 3PN 275
  • Design in accordance with EN 61643-11
  • Arrester type Type 1+2 (Class I+II, B+C, T1+T2)
  • Insertion type L-N: MOV (varistor), N-PE: GDT (spark gap)
  • Endurance voltage Uc L-N: 275 V AC, N-PE: 255 V AC
  • Frequency f 50-60Hz
  • Rated discharge current In (8/20 us) L-N: 20 kA per pole, N-PE: 40 kA per pole
  • Max. impulse current limp (10/350 us) L-N: 12.5 kA per pole, N-PE: 50 kA per pole
  • Max. discharge current Imax (8/20 us) 50 kA per pole
  • Voltage protection level Up for current In L-N: 1,5 kV, N-PE: 1.5 kV
  • Voltage protection level Up for current Imax L-N: 1.8 kV, N-PE: 1.5 kV
  • Voltage protection level Up for 5 kA (8/20 us) L-N: 2 kV, N-PE: 1.5 kV
  • N-PR fault current suppression capability Ifi 100A
  • Surge surges Ut (withstand) L-N: 5s : 335 V, N-PE: 200 ms : 1200 V
  • Arrester voltage for 1 mA current 387 - 473 V
  • Maximum fuse protection L-N: max. 160 A gG, N-PE: -
  • Short-circuit current withstand capability L-N: 50 kA, N-PE: -

DC SURGE ARRESTER USED T1+T2

  • Manufacturer/model PHOENIX/VAL-MS-T1/T2 1000DC-PV/2+V
  • Surge protection Type 1+2
  • Maximum permanent voltage UCPV 1050 V DC
  • Short-circuit immunity I SCPV 2000 A
  • Long-term operating current ICPV <20 uA
  • Rated load current IL 80 A
  • Protective conductor current IPE <=20 uA DC <=250 uA AC
  • Standby power consumption PC <=25 mVA
  • Rated discharge current (8/20) us 15 kA
  • Max. discharge current Imax (8/20) us 40 kA
  • Collected lightning current (10/350) us, load 2.5 As
  • Collected lightning current (10/350) us, specific energy 6,25 kJ/OM
  • Dissipated lightning current (10/350) us, peak Limp 5 kA
  • Total dissipated current Itotal (8/20) us 40 kA
  • Total dissipated current Itotal (10/350) us 5 kA
  • Protection level Up <= 3.5 kV
  • Residual voltage Ures <= 3.5 kV (at In)
  • <= 2,9 kV (at 5kA)
  • <= 3,2 kV (at 10kA)
  • <= 3.7 kV (at 20kA)
  • <= 4,1 kV (at 30kA)
  • <= 4.6 kV (at 40kA)
  • Response time tA <= 25ns
  • Insulation resistance Riso <= 5 Gigia OM (at 500 VDC)
More Information
EAN5906639360292
ManufacturerZineric
Warranty5
Inverter Min Power9
Inverter Max Power10
VoltageAC+DC
Number of Phase3-phase
Circuit Protection2
SPD TypesT1+T2
Width In Number Of Modular Spacings24.00
IP CodeIP65
ColourWhite