Zineric ZIN-BOX Solar Distribution Box AC DC 6-8kW 2String 3PH SPD T1T2 + B16 SPD T1T2

SKU
3191

Complete Zineric photovoltaic DC switchgear for self-assembly:

Price includes complete DC box for self-assembly:

  • 3 x module chain for 3 mppt
  • 3 x type 2 DC surge arrester
  • Ready to connect.
  • Modular design
  • MC4-compatible plug-in connection
  • For indoor and outdoor installation
  • Degree of protection IP65
  • Protection class II
  • White housing colour
  • Transparent door

The boxes are designed for use in photovoltaic installations with or without insulated lightning protection, also where a high degree of IP protection is required.

Their design is suitable for surface mounting.

Attention:

For ease of product navigation, it has been suggested to select the modular apparatus on the AC side under the inverter power and on the DC side under the number of MPPTs.

In each case, however, the inverter data sheet should be read in detail for correct selection of the switchgear and the appropriate Zineric switchgear should be selected by a qualified electrician.

ELECTRICAL AND MECHANICAL SPECIFICATIONS OF THE ENCLOSURE

  • Model PHS 24T
  • Number of modules 24
  • Design in accordance with EN 60670-1, EN 62208
  • Degree of protection IP65
  • Protection class II
  • Rated insulation voltage (Ui) 690 V AC, 1000 V DC
  • 650°C glow rod test
  • Impact resistance IK08
  • Halogen-free recyclable plastic

USED OVERCURRENT CIRCUIT BREAKER B16 3F

  • Manufacturer/model Noark/Ex9BN 3P B16
  • Rated current 16A; 3-phase
  • Number of poles 3
  • Characteristic B
  • Version according to IEC/EN 60898-1
  • Rated short-circuit breaking capacity ICN 6kA

AC T1+T2 SURGE ARRESTER USED

  • Manufacturer/model Phoenix VAL-MS-T1/T2 335/12.5/3+1
  • Design in accordance with EN 61643-11
  • Arrester type Type 1 + Type 2
  • Rated voltage UN 240/415 V AC (TN-S)
  • 240/415 V AC (TT)
  • Rated frequency fN 50 Hz (60 Hz)
  • Highest operational voltage UC (L-N) 335 V AC
  • Highest continuous voltage UC (L-PE) 335 V AC
  • Maximum operating voltage UC (N-PE) 264 V AC
  • Rated load current IL 80 A
  • Protective conductor current IPE <= 5 uA
  • Standby power consumption PC <= 810 mVA
  • Rated Dissipation Current In (8/20) µs (L-N) 12.5 kA
  • Rated Dissipation Current In (8/20) µs (L-PE) 12.5 kA
  • Rated discharge current In (8/20) µs (N-PE) 50 kA
  • Max. discharge current Imax (8/20) us 50 kA
  • Test lightning current (10/350) µs (L-N), charging 6,25 As
  • Test lightning current (10/350) µs (L-N), specific energy 39 kJ/ohm
  • Test lightning current (10/350) µs, (L-N) peak current Iimp12,5 kA
  • Test lightning current (10/350) µs (L-PE), charge 6,25 As
  • Test lightning current (10/350) µs (L-PE), specific energy 39 kJ/ohm
  • Test lightning current (10/350) µs, (L-PE) peak current Iimp 12,5 kA
  • Test lightning current (10/350) µs (N-PE), charge 25 As
  • Test lightning current (10/350) µs (N-PE), specific energy
  • Total dissipated current Itotal (8/20) µs 50 kA
  • Total dissipated current Itotal (10/350) µs 50 kA
  • 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA
  • Short-circuit withstand capability ISCCR 25 kA
  • Protection level Up (L-N) <= 1,2 kV
  • <= 1,6 kV (30 kA - 8/20 us)
  • UP (L-PE) protection level <= 2 kV
  • Protection level UP (N-PE) <= 1,7 kV
  • Residual voltage Ures (L-N) <= 1,2 kV (at In)
  • <= 1,1 kV (at 10 kA)
  • <= 1 kV (at 5 kA)
  • <= 0.9 kV (at 3 kA)
  • Residual voltage Ures (L-PE) <= 2 kV (at In)
  • <= 1.5 kV (at 10 kA)
  • <= 1,2 kV (at 5 kA)
  • <= 1.1 kV (at 3 kA)
  • Residual voltage Ures (N-PE) <= 0.6 kV (at In)
  • <= 0.5 kV (at 10 kA)
  • <= 0,5 kV (at 5 kA)
  • <= 0,4 kV (at 3 kA)
  • TOV behaviour for UT (L-N) 415 V AC (5 s / withstand mode)
  • 457 V AC (120 min / safe failure mode)
  • TOV behaviour for UT (N-PE) 1200 V AC (200 ms / withstand mode)
  • Tripping time tA (L-N) <= 25 ns
  • tripping time tA (L-PE) <= 100 ns
  • tripping time tA (N-PE) <= 100 ns
  • Maximum primary fuse in through installations V 80 A (gG - 16 mm2)
  • Maximum fuse value in installations in radial arrangement 160 A (gG)
More Information
EAN5906639360155
ManufacturerZineric
Weight3.850000
Warranty5
Inverter Min Power6
Inverter Max Power8
VoltageAC+DC
Number of Phase3-phase
Circuit Protection2
SPD TypesT1+T2
Width In Number Of Modular Spacings24.00
IP CodeIP65
ColourWhite