Complete Zineric DC+AC photovoltaic switchgear for self-assembly:

Characteristics:

  • 1 x module chain per 1 mppt
  • 1 x DC surge arrester type 1+2
  • 1 x type 1+2 AC surge arrester
  • 1 x 3-phase overcurrent circuit breaker 10A
  • MC4 board connections
  • Degree of protection IP65
  • Transparent door
  • Protection class: II
  • Colour: white

Distribution box suitable for photovoltaic systems in the power range 3-5kW

  • The boxes are designed for photovoltaic installations with or without lightning protection, also where a high IP degree of protection is required.
  • Their construction is suitable for surface mounting.

ELECTRICAL AND MECHANICAL CHARACTERISTICS OF THE HOUSING

  • Model PHS 12T
  • Number of modules 12
  • Version according to EN 60670-1, EN 62208
  • Degree of protection IP65
  • Protection class II
  • Rated insulation voltage (Ui) 690 V AC, 1000 V DC
  • 650°C glow rod test
  • Impact resistance IK08
  • Halogen-free recyclable plastic

AC SURGE PROTECTOR T1+T2 APPLIED

  • Manufacturer/model Noark/Ex9UE1+2 12.5 4P 275
  • Rated discharge current In (8/20 us) per phase 25kA
  • Maximum discharge current Imax (8/20 us) 50kA

DC SURGE ARRESTER USED T1+T2

  • Manufacturer/model PHOENIX/VAL-MS-T1/T2 1000DC-PV/2+V
  • Surge protection Type 1+2
  • Fault-tolerant Y-connection for applications according to VDE 0100-712 (IEC 60364-7-712)
  • Potential equalisation for surge protection in accordance with VDE 0100-443 (IEC 60364-4-44)
  • Current carrying capacity (8/20) per pole up to 50kA
  • Low DC voltage protection level (Uoc max = 1000V DC): <= 2.6kV
  • Replaceable inserts, with thermodynamic disconnection device and optical fault indication
  • Limiter Closed, blow-free varistor limiter on zinc oxide basis

USED OVERCURRENT CIRCUIT BREAKER B10 3F

  • Manufacturer/model Noark/Ex9BN 3P B10
  • Rated current 10A; 3-phase
  • Number of poles 3
  • Characteristic B
  • Version according to IEC/EN 60898-1
  • Rated short circuit breaking capacity ICN
More Information
ManufacturerZineric
Weight3.850000
Warranty5
Inverter Min Power3
Inverter Max Power5
VoltageAC+DC
Number of Phase3-phase
Circuit Protection1
SPD TypesT1+T2
Width In Number Of Modular Spacings12.00
IP CodeIP65
ColourWhite
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
More from Zineric
Copyright © 1992-present ecoABM sp. z o.o. All rights reserved.