Solar Distribution Box DC+AC 1String 1PH SPD T2 - B16 SPD T2

Login to See Price
0 pcs
Availability:
24h Bialystok
0 pcs
72h Central
0 pcs
SKU
2681
Solar Distribution Box DC+AC 1String 1PH SPD T2 - B16 SPD T2 is available to buy in increments of 1
DC and AC protection - 1f - in a single housing. Switchgear for self-assembly.

  • The boxes are designed for use in photovoltaic installations with or without lightning protection, also where a high IP degree of protection is required. Their construction is suitable for surface mounting
  • AC single-phase side.
Characteristics:
  • 1 x module chain, per 1 mppt
  • 1 x DC surge arrester type 2 - T2
  • 1 x AC surge arrester type 2 - T2
  • 1 x 1-phase overcurrent circuit breaker 16A
  • Backboard connections MC4
  • Degree of protection IP65
  • Transparent door
  • Protection class: II
  • Colour: white

ELECTRICAL AND MECHANICAL SPECIFICATIONS OF THE ENCLOSURE

  • Manufacturer - Noark
  • Model - PHS 8T
  • Number of modules - 8
  • Design - EN 60670-1, EN 62208
  • Degree of protection - IP65
  • Protection class - II
  • Rated insulation voltage (Ui) - 690 V AC, 1000 V DC
  • Glow rod test - 650°C
  • Impact resistance -IK08
  • Recyclable plastic - halogen-free

DC SURGE ARRESTER USED

  • Manufacturer / Model - PHOENIX / VAL-MS 1000DC-PV/2+V
  • Surge protection - Type 2
  • Maximum permanent voltage UCPV - 1170 V DC
  • Short-circuit immunity I SCPV - 2000 A
  • Long-term operating current ICPV - <20 uA
  • Rated load current IL - 80 A
  • Protective conductor current IPE - <=20 uA DC, <=250 uA AC
  • Standby power consumption PC - <=25 mVA
  • Rated discharge current (8/20) us - 15 kA
  • Max. discharge current Imax (8/20) us -40 kA
  • Total discharge current Itotal (8/20) us -40 kA
  • Protection level Up - <= 3,7 kV
  • Residual voltage Ures
  • <= 3,7 kV (at In)
  • <= 3,1 kV (at 5kA)
  • <= 3,5 kV (at 10kA)
  • <= 4 kV (at 20kA)
  • <= 4,6 kV (at 30kA)
  • <= 5 kV (at 40kA)
  • Response time tA - <= 25ns
  • Insulation resistance Riso - <= 5 Giga OM (at 500 VDC)

AC SURGE ARRESTER USED

  • Manufacturer - Noark
  • Model - Ex9UE2 12.5 3PN 275
  • Design in accordance with - EN 61643-11
  • Type - Type 2 (Class II, C, T2)
  • Insertion type - L-N: MOV (varistor), N-PE: GDT (spark gap)
  • Endurance voltage Uc - L-N: 275 V AC, N-PE: 255 V AC
  • Frequency f - 50-60Hz
  • Rated discharge current In (8/20 us) - L-N: 20 kA per pole, N-PE: 40 kA per pole
  • Max. impulse current limp (10/350 us) - N-PE: 12 kA per pole
  • Max. discharge current Imax (8/20 us) - 40 kA per pole
  • Voltage protection level Up for current In - L-N: 1,4 kV, N-PE: 1.5 kV
  • Voltage protection level Up for current Imax -L-N: 2 kV, N-PE: 1.5 kV
  • Voltage protection level Up for 5 kA (8/20 us) -L-N: 2 kV, N-PE: 1.5 kV
  • N-PR fault current suppression capability Ifi - 100A
  • Casual surges Ut (withstand) -L-N: 5s : 335 V, N-PE: 200 ms : 1200 V
  • Arrester voltage for 1 mA current - 387 - 473 V
  • Maximum fuse protection - L-N: max. 125 A gG, N-PE: -
  • Short-circuit current withstand capability -L-N: 50 kA, N-PE: -

OVERCURRENT CIRCUIT BREAKER INCORPORATED

  • Manufacturer - Noark
  • Model - Ex9BN 1P B16
  • Rated current - 16A; 1-phase
  • Number of poles - 1
  • Characteristics - B
  • Design - IEC/EN 60898-1
  • Rated short circuit breaking capacity ICN - 6kA
More Information
EAN4135262759826
ManufacturerecoABM
Weight1.580000
Warranty2
VoltageAC+DC
Number of Phase1-phase
Circuit Protection1
SPD TypesT2
Width In Number Of Modular Spacings8.00
IP CodeIP65