Solar Distribution Box DC+AC 1String 1PH SPD T2 - B16 SPD T2 RCD 40A 100mA

Solar Distribution Box DC+AC 1String 1PH SPD T2 - B16 SPD T2 RCD 40A 100mA is available to buy in increments of 1
DC and AC - 1F- protection in a single housing. Self-assembly switchgear.

  • The boxes are intended for use in photovoltaic installations with or without insulated lightning protection, also where a high IP degree of protection is required.
  • Their design is suitable for surface mounting.
  • AC side single-phase, version with earth leakage circuit breaker.
Characteristics:
  • 1 x module chain per 1 mppt
  • 1 x DC surge arrester type 2
  • 1 x type 2 AC surge arrester
  • 1 x 1-phase overcurrent circuit breaker 16A
  • 1 x current circuit breaker, 100mA, type A
  • Ready to connect
  • Modular version
  • MC4 panel connections
  • Degree of protection IP65
  • Transparent door
  • Protection class II
  • Colour: white
ELECTRICAL AND MECHANICAL CHARACTERISTICS OF THE ENCLOSURE:
  • Model PHS 12T
  • Number of modules 12
  • Design in compliance with EN 60670-1, EN 62208
  • Degree of protection IP65
  • Protection class II
  • Rated insulation voltage (Ui) 400 V AC, 1500 V DC
  • 650°C glow rod test
  • Impact resistance IK08
  • UV resistant YES
  • Halogen-free recyclable plastic
DC SURGE ARRESTER USED:
  • Manufacturer/model PHOENIX/VAL-MS 1000DC-PV/2+V
  • Surge protection Type 2
  • Maximum permanent voltage UCPV 1170 V DC
  • Short-circuit immunity I SCPV 2000 A
  • Long-term operating current ICPV <20 uA
  • Rated load current IL 80 A
  • Protective conductor current IPE <=20 uA DC <=250 uA AC
  • Standby power consumption PC <=25 mVA
  • Rated discharge current (8/20) us 15 kA
  • Max. discharge current Imax (8/20) us 40 kA
  • Total discharge current Itotal (8/20) us 40 kA
  • Protection level Up <= 3.7 kV
  • Residual voltage Ures <= 3.7 kV (at In) <= 3.1 kV (at 5kA) <= 3.5 kV (at 10kA) <= 4 kV (at 20kA) <= 4.6 kV (at 30kA) <= 5 kV (at 40kA)
  • Response time tA <= 25ns Insulation resistance Riso <= 5 Gigia OM (at 500 VDC)
*In case of low stock or lack of the right product, it is replaced by an equivalent product from the OBO manufacturer with index 5094608

OVERCURRENT CIRCUIT BREAKER USED:
  • Manufacturer/model Noark/Ex9BN 1P B16
  • Rated current 16A; 1-phase
  • Rated switching voltage Ue 230/400 V AC
  • Rated withstand surge voltage Uimp 4 kV
  • Rated insulation voltage Ui 690 V AC
  • Number of poles 1
  • Frequency 50/60 Hz
  • Characteristics B
  • Design compliant with IEC/EN 60898-1, IEC/EN 60947-2
  • Rated short-circuit breaking capacity ICN 6kA
AC SURGE ARRESTER USED:
  • Manufacturer/model Noark/Ex9UE2 12.5 3PN 275
  • Design in accordance with EN 61643-11
  • Type 2 (Class II, C, T2)
  • Insertion type L-N: MOV (varistor), N-PE: GDT (spark gap)
  • Endurance voltage Uc L-N: 275 V AC, N-PE: 255 V AC
  • Frequency f 50-60Hz
  • Rated discharge current In (8/20 us) L-N: 20 kA per pole, N-PE: 40 kA per pole
  • Max. Impulse current limp (10/350 us) N-PE: 12 kA per pole
  • Max. Discharge current Imax (8/20 us) 40 kA per pole
  • Voltage protection level Up for current In L-N: 1.4 kV, N-PE: 1.5 kV
  • Voltage protection level Up for current Imax L-N: 2 kV, N-PE: 1.5 kV
  • Voltage protection level Up for 5 kA (8/20 us) L-N: 2 kV, N-PE: 1.5 kV N-PR Follow-up current suppression capacity Ifi 100A
  • Surge surges Ut (withstand) L-N: 5s : 335 V, N-PE: 200 ms : 1200 V
  • Arrester voltage for 1 mA current 387 - 473 V
  • Maximum fuse rating L-N: max. 125 A gG, N-PE: -
  • Short-circuit withstand capability L-N: 50 kA, N-P
CIRCUIT-BREAKER USED:
  • Model Ex9L-N 100mA
  • Version according to EN 61008
  • Rated switching voltage Ue 240/415 V AC
  • Min. voltage for the function of the circuit-breaker Independent of voltage
  • Voltage range for text button 150 - 440 V
  • Frequency f 50 Hz
  • Rated conditional fault current Inc 6 kA
  • Rated residual current In 100 mA
  • Sensitivity to sinusoidal and pulsed rectified differential current
  • Tripping time without delay
  • Rated withstand surge voltage Uimp 6 kV
  • Rated insulation voltage Ui 500 V
  • Surge current strength 3000 A
  • Mechanical endurance 20,000 laps
  • Electrical life 4,000 connections
  • Max. fuse overload protection In = 40A max. 32 A gG
  • Max. overload fuse protection In = 63A max. 50 A gG
  • Max. short circuit proof fuse In = 40A max. 63 A gG
  • Fuse protection against short circuit In = 63A max. 63 A gG
  • Rated breaking capacity Im (Rated differential breaking capacity IDm) In = 40A 500 A
  • Rated switching capacity Im (Rated differential switching capacity IDm) In = 63A 630 A
  • Supply direction Any (from above or below)
More Information
EAN4135265664400
ManufacturerecoABM
Weight2.620000
Warranty2
VoltageAC+DC
Number of Phase1-phase
Circuit Protection1
SPD TypesT2
Width In Number Of Modular Spacings12.00
IP CodeIP65