Solar Distribution Box AC 3PH B20 SPD T2 RCD 40A 300mA
SKU
1819
The boxes are designed for use in photovoltaic installations with or without insulated lightning protection, also where a high IP degree of protection is required. Their construction is suitable for surface mounting
The price includes a complete AC box for self-assembly:
- 1 x type 2 AC surge arrester
- 1 x 3-phase overcurrent circuit breaker 20A
- 1 x residual current circuit breaker, 300mA
- Ready to connect
- Modular design
- Degree of protection IP65
- Transparent door
- Protection class II
- Colour: white
ELECTRICAL AND MECHANICAL SPECIFICATIONS OF THE ENCLOSURE
- Model PHS 12T
- Number of modules 12
- Design in compliance with EN 60670-1, EN 62208
- Degree of protection IP65
- Protection class II
- Rated insulation voltage (Ui) 690 V AC, 1000 V DC
- 650°C glow rod test
- Impact resistance IK08
- Halogen-free recyclable plastic
RESIDUAL CURRENT CIRCUIT BREAKER USED
- Model Ex9L-N 300mA
- Design in accordance with EN 61008
- Rated switching voltage Ue 240/415 V AC
- Min. voltage for residual-current circuit-breaker function Voltage independent
- Voltage range for text button 150 - 440 V
- Frequency f 50 Hz
- Rated conditional fault current Inc 6 kA
- Rated residual current In 300 mA
- Sensitivity to sinusoidal and pulsed rectified differential current
- Tripping time without delay
- Rated withstand surge voltage Uimp 6 kV
- Rated insulation voltage Ui 500 V
- Surge current strength 3000 A
- Mechanical endurance 20,000 switching operations
- 4,000 switching cycles
- Overload fuse protection max. 32 A gG
- Fuse protection against short-circuit effects max. 63 A gG
- Rated breaking capacity Im (Rated breaking capacity IDm) 500 A
- Direction of power supply Any (from above or below)
OVERCURRENT CIRCUIT BREAKER USED
- Manufacturer/model Noark/Ex9BN 3P B20
- Rated current 20A; 3-phase
- Number of poles 3
- Characteristics B
- Version according to IEC/EN 60898-1
- Rated short circuit breaking capacity ICN 6kA
AC SURGE ARRESTER USED
- Manufacturer/model Noark/Ex9UE2 12.5 3PN 275
- Design in accordance with EN 61643-11
- Type 2 (Class II, C, T2)
- Insertion type L-N: MOV (varistor), N-PE: GDT (spark gap)
- Endurance voltage Uc L-N: 275 V AC, N-PE: 255 V AC
- Frequency f 50-60Hz
- Rated discharge current In (8/20 us) L-N: 20 kA per pole, N-PE: 40 kA per pole
- Max. impulse current limp (10/350 us) N-PE: 12 kA per pole
- Max. discharge current Imax (8/20 us) 40 kA per pole
- Voltage protection level Up for current In L-N: 1,4 kV, N-PE: 1.5 kV
- Voltage protection level Up for current Imax L-N: 2 kV, N-PE: 1.5 kV
- Voltage protection level Up for 5 kA (8/20 us) L-N: 2 kV, N-PE: 1.5 kV
- N-PR fault current suppression capability Ifi 100A
- Surge surges Ut (withstand) L-N: 5s : 335 V, N-PE: 200 ms : 1200 V
- Arrester voltage for 1 mA current 387 - 473 V
- Maximum fuse protection L-N: max. 125 A gG, N-PE: -
- Short-circuit current withstand capability L-N: 50 kA, N-PE: -
EAN | 4129722810622 |
---|---|
Manufacturer | ecoABM |
Weight | 3.000000 |
Warranty | 2 |
Voltage | AC |
Number of Phase | 3-phase |
SPD Types | T2 |
Width In Number Of Modular Spacings | 12.00 |
IP Code | IP65 |
Width | 31.00 cm |
Height | 17.00 cm |
Length/Depth | 33.00 cm |