Solar Distribution Box AC 3PH B25 SPD T1T2 RCD 40A 300mA

SKU
1820
The boxes are designed for use in photovoltaic installations with or without insulated lightning protection, also where a high IP degree of protection is required. Their construction is suitable for surface mounting

The price includes a complete AC box for self-assembly:

  • 1 x type 1+2 AC surge arrester
  • 1 x 3-phase overcurrent circuit breaker 25A
  • 1 x residual current circuit breaker, 300mA
  • Ready to connect
  • Modular design
  • Degree of protection IP65
  • Transparent door
  • Protection class II
  • Colour: white

ELECTRICAL AND MECHANICAL SPECIFICATIONS OF THE ENCLOSURE

  • Model PHS 12T
  • Number of modules 12
  • Design in compliance with EN 60670-1, EN 62208
  • Degree of protection IP65
  • Protection class II
  • Rated insulation voltage (Ui) 690 V AC, 1000 V DC
  • 650°C glow rod test
  • Impact resistance IK08
  • Halogen-free recyclable plastic

OVERCURRENT CIRCUIT BREAKER USED

  • Manufacturer/model Noark/Ex9BN 3P B25
  • Rated current 25A; 3-phase
  • Number of poles 3
  • Characteristic B
  • Version according to IEC/EN 60898-1
  • Rated short-circuit breaking capacity ICN 6kA

AC SURGE ARRESTER USED

  • Manufacturer/model Noark/Ex9UE1+2 12.5 3PN 275
  • Design in accordance with EN 61643-11
  • Type of arrester Type 1+2 (Class I+II, B+C, T1+T2)
  • Insertion type L-N: MOV (varistor), N-PE: GDT (spark gap)
  • Endurance voltage Uc L-N: 275 V AC, N-PE: 255 V AC
  • Frequency f 50-60Hz
  • Rated discharge current In (8/20 us) L-N: 20 kA per pole, N-PE: 40 kA per pole
  • Max. impulse current limp (10/350 us) L-N: 12.5 kA per pole, N-PE: 50 kA per pole
  • Max. discharge current Imax (8/20 us) 50 kA per pole
  • Voltage protection level Up for current In L-N: 1,5 kV, N-PE: 1.5 kV
  • Voltage protection level Up for current Imax L-N: 1.8 kV, N-PE: 1.5 kV
  • Voltage protection level Up for 5 kA (8/20 us) L-N: 2 kV, N-PE: 1.5 kV
  • N-PR fault current suppression capability Ifi 100A
  • Surge surges Ut (withstand) L-N: 5s : 335 V, N-PE: 200 ms : 1200 V
  • Arrester voltage for 1 mA current 387 - 473 V
  • Maximum fuse protection L-N: max. 160 A gG, N-PE: -
  • Short-circuit current withstand capability L-N: 50 kA, N-PE: -

CIRCUIT-BREAKER USED

  • Model Ex9L-N 300A
  • Version according to EN 61008
  • Rated switching voltage Ue 240/415 V AC
  • Min. voltage for disconnection/circuit-breaker function Voltage independent
  • Voltage range for text button 150 - 440 V
  • Frequency f 50 Hz
  • Rated conditional fault current Inc 6 kA
  • Rated residual current In 300 mA
  • Sensitivity to sinusoidal and pulsed rectified differential current
  • Tripping time without delay
  • Rated withstand surge voltage Uimp 6 kV
  • Rated insulation voltage Ui 500 V
  • Surge current strength 3000 A
  • Mechanical endurance 20,000 switching operations
  • 4,000 switching cycles
  • Overload fuse protection max. 32 A gG
  • Fuse protection against short-circuit effects max. 63 A gG
  • Rated breaking capacity Im (Rated breaking capacity IDm) 500 A
  • Direction of power supply Any (from above or below)
More Information
EAN4131296905758
ManufacturerecoABM
Weight2.950000
Warranty2
VoltageAC
Number of Phase3-phase
SPD TypesT1+T2
Width In Number Of Modular Spacings12.00
IP CodeIP65
Width30.00 cm
Height33.00 cm
Length/Depth16.00 cm
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
More from ecoABM
  1. Copper Tube Terminal 16mm M10
    Copper Tube Terminal 16mm M10
  2. Copper Tube Terminal 10mm M10
    Copper Tube Terminal 10mm M10
  3. Copper Tube Terminal 16mm M8
    Copper Tube Terminal 16mm M8
Copyright © 1992-present ecoABM sp. z o.o. All rights reserved.