Solar Distribution Box AC 3PH B25 SPD T1T2 RCD 40A 300mA
SKU
1820
Solar Distribution Box AC 3PH B25 SPD T1T2 RCD 40A 300mA is available to buy in increments of 1
The boxes are designed for use in photovoltaic installations with or without insulated lightning protection, also where a high IP degree of protection is required. Their construction is suitable for surface mounting
The price includes a complete AC box for self-assembly:
- 1 x type 1+2 AC surge arrester
- 1 x 3-phase overcurrent circuit breaker 25A
- 1 x residual current circuit breaker, 300mA
- Ready to connect
- Modular design
- Degree of protection IP65
- Transparent door
- Protection class II
- Colour: white
ELECTRICAL AND MECHANICAL SPECIFICATIONS OF THE ENCLOSURE
- Model PHS 12T
- Number of modules 12
- Design in compliance with EN 60670-1, EN 62208
- Degree of protection IP65
- Protection class II
- Rated insulation voltage (Ui) 690 V AC, 1000 V DC
- 650°C glow rod test
- Impact resistance IK08
- Halogen-free recyclable plastic
OVERCURRENT CIRCUIT BREAKER USED
- Manufacturer/model Noark/Ex9BN 3P B25
- Rated current 25A; 3-phase
- Number of poles 3
- Characteristic B
- Version according to IEC/EN 60898-1
- Rated short-circuit breaking capacity ICN 6kA
AC SURGE ARRESTER USED
- Manufacturer/model Noark/Ex9UE1+2 12.5 3PN 275
- Design in accordance with EN 61643-11
- Type of arrester Type 1+2 (Class I+II, B+C, T1+T2)
- Insertion type L-N: MOV (varistor), N-PE: GDT (spark gap)
- Endurance voltage Uc L-N: 275 V AC, N-PE: 255 V AC
- Frequency f 50-60Hz
- Rated discharge current In (8/20 us) L-N: 20 kA per pole, N-PE: 40 kA per pole
- Max. impulse current limp (10/350 us) L-N: 12.5 kA per pole, N-PE: 50 kA per pole
- Max. discharge current Imax (8/20 us) 50 kA per pole
- Voltage protection level Up for current In L-N: 1,5 kV, N-PE: 1.5 kV
- Voltage protection level Up for current Imax L-N: 1.8 kV, N-PE: 1.5 kV
- Voltage protection level Up for 5 kA (8/20 us) L-N: 2 kV, N-PE: 1.5 kV
- N-PR fault current suppression capability Ifi 100A
- Surge surges Ut (withstand) L-N: 5s : 335 V, N-PE: 200 ms : 1200 V
- Arrester voltage for 1 mA current 387 - 473 V
- Maximum fuse protection L-N: max. 160 A gG, N-PE: -
- Short-circuit current withstand capability L-N: 50 kA, N-PE: -
CIRCUIT-BREAKER USED
- Model Ex9L-N 300A
- Version according to EN 61008
- Rated switching voltage Ue 240/415 V AC
- Min. voltage for disconnection/circuit-breaker function Voltage independent
- Voltage range for text button 150 - 440 V
- Frequency f 50 Hz
- Rated conditional fault current Inc 6 kA
- Rated residual current In 300 mA
- Sensitivity to sinusoidal and pulsed rectified differential current
- Tripping time without delay
- Rated withstand surge voltage Uimp 6 kV
- Rated insulation voltage Ui 500 V
- Surge current strength 3000 A
- Mechanical endurance 20,000 switching operations
- 4,000 switching cycles
- Overload fuse protection max. 32 A gG
- Fuse protection against short-circuit effects max. 63 A gG
- Rated breaking capacity Im (Rated breaking capacity IDm) 500 A
- Direction of power supply Any (from above or below)
EAN | 4131296905758 |
---|---|
Manufacturer | ecoABM |
Weight | 2.950000 |
Warranty | 2 |
Voltage | AC |
Number of Phase | 3-phase |
SPD Types | T1+T2 |
Width In Number Of Modular Spacings | 12.00 |
IP Code | IP65 |
Width | 30.00 cm |
Height | 33.00 cm |
Length/Depth | 16.00 cm |