Solar Distribution Box AC 3PH B16 SPD T2 RCD 40A 300mA

Solar Distribution Box AC 3PH B16 SPD T2 RCD 40A 300mA is available to buy in increments of 1
The boxes are designed for use in photovoltaic installations with or without insulated lightning protection, also where a high IP degree of protection is required. Their construction is suitable for surface mounting

The price includes a complete AC box for self-assembly:

  • 1 x type 2 AC surge arrester
  • 1 x 3-phase overcurrent circuit breaker 16A
  • 1 x residual current circuit breaker, 300mA
  • Ready to connect
  • Modular design
  • Degree of protection IP65
  • Transparent door
  • Protection class II
  • Colour: white

ELECTRICAL AND MECHANICAL SPECIFICATIONS OF THE ENCLOSURE

  • Model PHS 12T
  • Number of modules 12
  • Design in compliance with EN 60670-1, EN 62208
  • Degree of protection IP65
  • Protection class II
  • Rated insulation voltage (Ui) 690 V AC, 1000 V DC
  • 650°C glow rod test
  • Impact resistance IK08
  • Halogen-free recyclable plastic

OVERCURRENT CIRCUIT BREAKER USED

  • Manufacturer/model Noark/Ex9BN 3P B16
  • Rated current 16A; 3-phase
  • Number of poles 3
  • Characteristic B
  • Version according to IEC/EN 60898-1
  • Rated short-circuit breaking capacity ICN 6kA

AC SURGE ARRESTER USED

  • Manufacturer/model Noark/Ex9UE2 12.5 3PN 275
  • Design in accordance with EN 61643-11
  • Arrester type Type 2 (Class II, C, T2)
  • Insertion type L-N: MOV (varistor), N-PE: GDT (spark gap)
  • Endurance voltage Uc L-N: 275 V AC, N-PE: 255 V AC
  • Frequency f 50-60Hz
  • Rated discharge current In (8/20 us) L-N: 20 kA per pole, N-PE: 40 kA per pole
  • Max. impulse current limp (10/350 us) N-PE: 12 kA per pole
  • Max. discharge current Imax (8/20 us) 40 kA per pole
  • Voltage protection level Up for current In L-N: 1,4 kV, N-PE: 1.5 kV
  • Voltage protection level Up for current Imax L-N: 2 kV, N-PE: 1.5 kV
  • Voltage protection level Up for 5 kA (8/20 us) L-N: 2 kV, N-PE: 1.5 kV
  • N-PR fault current suppression capability Ifi 100A
  • Surge surges Ut (withstand) L-N: 5s : 335 V, N-PE: 200 ms : 1200 V
  • Arrester voltage for 1 mA current 387 - 473 V
  • Maximum fuse protection L-N: max. 125 A gG, N-PE: -
  • Short-circuit current withstand capability L-N: 50 kA, N-PE: -
More Information
EAN4129769707114
ManufacturerecoABM
Weight2.800000
Warranty2
VoltageAC
Number of Phase3-phase
SPD TypesT2
Width In Number Of Modular Spacings12.00
IP CodeIP65
Width33.00 cm
Height17.00 cm
Length/Depth30.50 cm
Write Your Own Review