Rotenso Aquami AQS140X3o Heat Pump 14kW Split 3PH Outdoor unit

Rotenso Aquami AQS140X3o Heat Pump 14kW Split 3PH Outdoor unit is available to buy in increments of 1

Rotenso Aquami Split heatpump AQS140X3o R13 (outdoor unit)

The Rotenso Aquami Split 14 kW (three-phase) heat pump consists of:

  • an outdoor unit with the symbol AQS140X3o
  • a hydraulic module with the symbol AQS160X13i.

This is a three-phase pump with a heating capacity of 14.5 kW (A7/W35) and high energy efficiency class A+++ (for 35° flow temperature) and A++ (for 55° flow temperature). It provides high heating capacity down to an outdoor temperature of -25°C and can operate without the aid of electric heaters even at an ambient temperature of -15°C. The maximum available water temperature in heating mode is: 65°C and in DHW mode it is: 60°C.

To ensure trouble-free operation at temperatures below 0°C, the pump is fitted with a drip tray heater to prevent condensate from freezing and the external unit from frosting, thus preventing possible damage to the fan and heat pump exchanger.
The second important element of the pump's equipment is the compressor crankcase heater which, at temperatures below 0°, heats the compressor oil preparing the unit for trouble-free start-up in adverse weather conditions.
This technical solution guarantees failure-free operation and extends the life of the compressor - the heart of the heat pump.

The AQS140X3o heat pump is equipped with a 9 kW modulating booster heater (3 kW + 3 kW + 3 kW). In emergency situations or at temperatures below -15° C, it is sometimes advisable for the heat pump to use booster heaters to prepare hot water or DHW for economical operation of the heat pump. It is worth bearing in mind that the use of heaters has a beneficial effect on the durability and reliability of the heat pump.
It is worth bearing in mind that in emergency and extreme situations, these heaters may take over as the only source of heat.

The Rotenso Aquami AQS140X3o heat pump is a day-to-day user-friendly unit. Easy service access is provided by the placement of the automation and hydraulic components in the indoor unit and the USB function allows the pump's software to be quickly updated . Simply copy the stored parameters between the controllers using a memory stick. The use of a single-fan design with a bionic vane pattern, a two-rotary compressor and optimisation of the piping design have significantly contributed to the quiet operation of the pump.

The Rotenso Aquami pump can be controlled from a mobile app as well as a modern wired controller with a menu in Polish.

The Rotenso Aquami Split 14 kW set comprises:

  • outdoor unit AQS140X3o
  • indoor unit AQS160X13i
  • wired controller
  • DHW tank sensor
  • plate heat exchanger
  • flow sensor
  • diaphragm vessel
  • manometer
  • water pump
  • safety valve
  • vent valve
  • Y-type water filter

Specifications

  • Power supply (V-Hz, Ø)380-420~50, 3f
  • Heating (A7/W35) / Output (kW) 14.5
  • Heating (A7/W35) / Power consumption (kW) 3.09
  • Heating (A7/W35) / COP 4.7
  • Heating (A7/W45) / Efficiency (kW) 14.2
  • Heating (A7/W45) / Power input (kW) 3.89
  • Heating (A7/W45) / COP 3.65
  • Heating (A7/W55) / Efficiency (kW) 13.8
  • Heating (A7/W55) / Power input (kW) 4.6
  • Heating (A7/W55) / COP 3
  • Cooling (A35/W18) / Capacity (kW) 13.5
  • Cooling (A35/W18) / Power input (kW) 3.75
  • Cooling (A35/W18) / EER 3.6
  • Cooling (A35/W7) / Efficiency (kW) 12.7
  • Cooling (A35/W7) / Power input (kW) 4.98
  • Cooling (A35/W7) / EER 2.55
  • Seasonal energy efficiency TWW at 35°C / Rated heat output (kW) 4.72
  • Seasonal energy efficiency TWW at 35°C / SCOP (1) 13.7
  • Seasonal energy efficiency TWW at 35°C / Seasonal energy efficiency ratio (ηS) (%) 185.7
  • Seasonal energy efficiency TWW at 35°C / Annual energy consumption (kWh) 6,012
  • Seasonal energy efficiency class for space heating (1) A+++
  • Seasonal energy efficiency TWW at 55°C / SCOP (1) 3.47
  • Seasonal energy efficiency TWW at 55°C / Rated heat output (kW) 12.1
  • Seasonal energy efficiency TWW at 55°C / Seasonal energy efficiency ratio (ηS) (%) 135.6
  • Seasonal energy efficiency TWW at 55°C / Annual energy consumption (kWh) 7,202
  • Seasonal energy efficiency ratio TWW at 55°C / Seasonal energy efficiency class fenestration (1) A++
  • SEER / TWW at 7°C 4.83
  • SEER / TWW at 18°C 6.85
  • Maximum overcurrent protection (MZN) (A) 14
  • Minimum circuit overload (MOO) (A) 11
  • Compressor (Type) Two-rotary DC compressor
  • Fan (Type) Brushless DC
  • Fan (Number) 1
  • Refrigerant (Type) R32
  • Refrigerant / GWP 675
  • Refrigerant / quantity (up to 15mb) (kg) 1.84
  • Refrigerant / Quantity (up to 15 nm) (TCO2eq) 1.24
  • Pipe connections / Liquid (mm) Φ9,52 (3/8"")
  • Pipe connections / Gas (mm) Φ15,9 (5/8"")
  • Pipe connections / Minimum installation length (m) 2
  • Pipe connections / Maximum installation length (m) 30
  • Pipe connections / Additional amount of refrigerant above 15 m (g/m) 38
  • Maximum level difference / outdoor unit above indoor unit (m) 20
  • Maximum level difference / outdoor unit below indoor unit (m) 20
  • Supply lines: outdoor unit (number x mm ²) 5 × 2.5
  • Control cables: indoor-indoor unit (Nr. x mm²) 2 × 0.75 (shielded)
  • Mounting spacing (SxG) (mm) 656×456
  • Sound pressure level (dB(A)) 52,2
  • Sound power level (dB(A)) 65
  • Net dimensions (SxGxW) (mm) 1118×864×523
  • Gross dimensions (SxGxW) (mm) 1180×890×560
  • Net weight / Gross weight (kg) 116/129.5
  • Outdoor operation range / Cooling (°C) -5~43
  • Outdoor operation range/heating (°C) -25~35
  • Outdoor operation range / DHW (°C) -25~43
More Information
ManufacturerRotenso
Weight129.500000
Warranty5
Power kW14.00 kW
Number of Phase3-phase
RefrigerantsR32
ColourWhite
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account