Noark 100051 MCB Ex9BN 3P B10 AC Miniature Circuit Breaker

Login to See Price
2 pcs
Availability:
24h Bialystok
2 pcs
72h Central
0 pcs
SKU
3322
Noark 100051 MCB Ex9BN 3P B10 AC Miniature Circuit Breaker is available to buy in increments of 1

S 3-phase overcurrent circuit breaker B 10A 3P 400V NOARK 100051

Specification:

  • Manufacturer: Noark
  • Type: Overcurrent circuit breaker
  • Rated voltage: 400V
  • Possibility of additional equipment: Yes
  • Number of poles (total): 3
  • Number of poles: 3
  • Voltage type: AC
  • Energy limitation class: 3
  • Surge protection category: 3
  • Insertion depth: 74 mm
  • Tripping characteristic: B
  • Width expressed in number of modules: 3
  • Degree of protection: IP20
  • Suitable for flush-mounted installations: Yes
  • Degree of contamination: 2
  • Rated current: 10A
  • N pole simultaneously disconnectable: No
  • Rated short-circuit breaking capacity (Icn) EN 60898 at 230V: 6kA
  • Rated short-circuit breaking capacity (Icu) IEC 60947-2 at 230V: 10kA

Series information:

  • Modular overcurrent circuit breakers of the Ex9BN series are versatile devices designed for a wide range of applications, meeting stringent standards for domestic use in accordance with EN 60898. They are designed to operate in the current rating range from 1 to 63 A.
  • The NOARK 100051 overcurrent circuit breaker has a rated short-circuit breaking capacity Icn of 6kA, which applies to all breaker versions, i.e. up to 63 A rated current and B, C, D trip characteristics.
  • The pole width of the circuit breaker corresponds to one module (18mm) and the Ex9BN series is fully compliant with the standards for mechanical performance.
  • In addition, the Ex9BN series circuit breakers can be combined with a wide range of accessories, including auxiliary contacts, auxiliary trip contacts, rise, undervoltage, overvoltage and residual current blocks. A wide variety of accessory combinations can be created, limited only by their number and not their type - all components are mutually compatible.
  • Up to a maximum of three auxiliary contact or trip contact units and up to two trip units can be fitted.
More Information
ManufacturerNoark Electric
Weight0.000000
VoltageAC
Number of Phase3-phase
Width In Number Of Modular Spacings3.00
Width0.00 cm
Height0.00 cm
Length/Depth0.00 cm
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
More from Noark Electric
Copyright © 1992-present ecoABM sp. z o.o. All rights reserved.