Solar Cable 6mm H1Z2Z2-K Red
SKU
1770
Solar Cable 6mm H1Z2Z2-K Red is available to buy in increments of 1
Solar cable with double insulation 6mm2 x 1m red
The cable has been specially designed for photovoltaic installations. Thanks to its double insulation it is resistant to all kinds of weather conditions.
PV cable (solar cable) refers to the original design made by the PV working team.
CABLE DESIGN
1. Multi-strand conductor - soft wires made of copper
2. Insulation - cross-linked, halogen-free material
3. Outer sheath - cross-linked material, halogen-free, red colour
APPLICATION
The cable has been specially designed for photovoltaic installations. Thanks to its double insulation it is resistant to all kinds of weather conditions.
PV cable (solar cable) refers to the original design made by the PV working team.
CABLE DESIGN
1. Multi-strand conductor - soft wires made of copper
2. Insulation - cross-linked, halogen-free material
3. Outer sheath - cross-linked material, halogen-free, red colour
APPLICATION
- The cables are designed specifically for use in solar power generation.
- They are used to connect photovoltaic panels.
- The cable is suitable for outdoor and indoor use.
- Suitable for photovoltaic installations mounted on roofs as well as on the ground.
- Very high resistance to solar radiation.
- Highest-quality fire-resistant materials are used for safety.
- Nominal AC voltage: U0/U 0.6/1.0 kV
- Max. DC voltage of PV system: 1.5 kV
- Max. permissible AC operating voltage: 0.6/1.0 kV conductor-to-ground/conductor-to-conductor
- Max. permissible operating DC voltage: 0.9/1.5 kV conductor-to-ground/conductor-to-wire
- AC/DC voltage test: 4.0 kV
- Current-carrying capacity: According to requirements for cables for PV systems TÜV 2 PFG 1169/08.2007
- Mechanical load resistance: 15 N/mm2 in use, 50 N/mm2 during installation
- Bending radius: Min. 3 x D (D = max. outer diameter)
- Abrasion with sandpaper: (int. test according to DIN 53516), coating with coating (int. test), coating with metal (int. test), coating with plastic (int. test)
- Shore hardness: 85 (int. test in accordance with DIN 53505)
- Rodent-proof: For adequate protection, use metal or plastic braided protective tubes
- Nominal cross-section [mm2]: 6 mm2
- Conductor diameter [mm]: 2.9
- Outside diameter (minimum) [mm]: 5.7
- Outer diameter (maximum) [mm]: 6.1
- Permissible short-circuit current (1s) [kA]: 0.76
- Minimum bend radius [mm]: 18
- Net cable weight (approximate) [kg/km]: 77
- Maximum load current at 60oC [A]: 70
- Maximum permissible tensile load [N]: 90
- Resistance to external agents
- Resistance to petrol: 24 h, 100°C (int. test in accordance with DIN VDE 0473 811-2-1, DIN EN 60811-2-1)
- Ozone resistance: according to DIN EN 50396, HD 22.2 type B test
- UV resistance: According to UL 1581 (xeno test), ISO 4892-2 (meth. 1), HD 605/A1-2.4.20
- Acid and alkaline resistance: according to EN 60811-2-1, 7 days, 23 °C (N oxalic acid, N sodium hydroxide solution)
- Ammonia resistance: 30 days saturated with ammonia atmosphere
- Water absorption: Test according to DIN EN 60811-1-3
- Reaction to fire
- Spread of fire: DIN EN 60332-1-2 and TÜV 2 PfG 1169/08.2007
- Smoke emission, light transmission: In accordance with IEC 61034 and DIN VDE 0482 part 268-2
- Fire propagation, cable bundling: In accordance with DIN EN 50305-9 and DIN VDE 0482 part 332-3-25
- Environmental safety: ROHS
EAN | 4128666280430 |
---|---|
Manufacturer | Other |
Weight | 0.080000 |
Warranty | 2 |
Voltage | DC |
Colour | Red |
Width | 0.70 cm |
Height | 0.70 cm |
Length/Depth | 100.00 cm |