The Rotenso Heatmi Split 14 kW heat pump consists of:

  • indoor unit: hydraulic module with the symbol HES140X13i (to be purchased separately)
  • an outdoor unit with the HES140X3o symbol.

This is a three-phase pump with a heating capacity of 14.50 kW (A7/W35) and high energy efficiency class A++ (for 35° flow temperature) and A++ (for 55° flow temperature). The COP for A7/W35 is as high as 4.75.

It provides high heating capacity down to an outdoor temperature of -25°C.

The maximum available water temperature in heating mode is: 65°C and in DHW mode it is: 60°C.

The pump has a 2-rotation inverter compressor. Refrigerant - R32.

In order to ensure trouble-free operation at temperatures below 0°C, the pump is equipped with a drip tray heater to prevent the condensate from freezing and the external unit from frosting, thus preventing possible damage to the fan and heat pump exchanger.

The second important piece of equipment is the compressor crankcase heater, which heats the compressor oil at temperatures below 0°C and prepares the unit for trouble-free start-up in adverse weather conditions.

This technical solution guarantees trouble-free operation and extends the service life of the compressor - the heart of the heat pump.

The Heatmi Split 14 kW heat pump is equipped with a 9 kW modulating booster heater (3 kW +3 kW + 3 kW).

In emergency situations or at temperatures below the bivalent point, it is advisable for the pump to make use of the booster heaters when preparing hot water for central heating or DHW.

It is worth knowing that the use of heaters has a beneficial effect on the durability and reliability of the heat pump.

The Rotenso Heatmi pump can be controlled from a mobile application (Tuya Smart) as well as a modern wired controller with a menu in Polish, which has a built-in room temperature sensor and a Wi-Fi module.

The Rotenso Heatmi Split 14 kW set comprises:

  • HES140X3o outdoor unit
  • indoor unit HES140X13i (to be purchased separately)
  • wired controller
  • DHW tank sensor
  • plate heat exchanger
  • flow sensor
  • diaphragm vessel
  • manometer
  • water pump
  • safety valve
  • vent valve
  • Y-type water filter

Specifications:

  • Model HES140X3o
  • Rotenso Heatmi series
  • Compatible indoor unit model HES140X13i
  • Power supply (V-Hz, Ø) 380-420~50, 3f
  • Heating (A7/W35) / Efficiency (kW) 14.5
  • Heating (A7/W35) / Power consumption (kW) 3.05
  • Heating (A7/W35) / COP 4.75
  • Heating (A7/W45) / Efficiency (kW) 14.3
  • Heating (A7/W45) / Power input (kW) 3.83
  • Heating (A7/W45) / COP 3.73
  • Heating (A7/W55) / Efficiency (kW) 14
  • Heating (A7/W55) / Power input (kW) 4.65
  • Heating (A7/W55) / COP 3.01
  • Cooling (A35/W18) / Efficiency (kW) 13.5
  • Cooling (A35/W18) / Power input (kW) 3.6
  • Cooling (A35/W18) / EER 3.75
  • Cooling (A35/W7) / Efficiency (kW) 13
  • Cooling (A35/W7) / Power consumption (kW) 4.98
  • Cooling (A35/W7) - EER 2.6
  • Air-to-water ∙ Seasonal energy efficiency TWW at 35⁰C ∙ SCOP 4.74
  • Air-to-water ∙ Seasonal energy efficiency TWW at 35⁰C ∙ Rated heating output (kW) 13.7
  • Air-to-water ∙ Seasonal energy efficiency TWW at 35⁰C ∙ Seasonal energy efficiency ratio (ηS) (%) 185
  • Air-water ∙ Seasonal energy efficiency TWW at 35⁰C ∙ Annual energy consumption (kWh) 5990
  • Air-water ∙ Seasonal energy efficiency TWW at 35⁰C ∙ Seasonal energy efficiency class for space heating (1) A+++
  • Air-water ∙ Seasonal energy efficiency TWW at 55⁰C ∙ SCOP (1) 3.45
  • Air-to-water � Seasonal energy efficiency TWW at 55⁰C � Rated heating output (kW) 12.1
  • Air-to-water ∙ Seasonal energy efficiency TWW at 55⁰C ∙ Seasonal energy efficiency ratio(ηS) (%) 135
  • Air-to-water ∙ Seasonal energy efficiency TWW at 55⁰C ∙ Annual energy consumption (kWh) 7787
  • Air-to-water ∙ Seasonal energy efficiency TWW at 55⁰C ∙ Seasonal energy efficiency class for space heating (1 A++
  • SEER / TWW at 7°C 4.85
  • SEER / TWW at 18°C 6.95
  • Maximum overcurrent protection (MZN) (A) 16
  • Minimum circuit overload (MOO) (A) 11
  • Compressor (Type) Double cycle DC compressor
  • Fan (Type) Brushless DC
  • Fan (Number) 1
  • Refrigerant (Type) R32
  • Refrigerant / GWP 675
  • Refrigerant / quantity (up to 15mb) (kg) 1.84
  • Refrigerant / Quantity (up to 15mb) (TCO2eq) 1.242
  • Pipe connections / Liquid / Gas (mm (inch)) Φ9,52 / Φ15,9
  • Pipe connections / Minimum installation length (m) 2
  • Pipe connections / Maximum installation length (m) 30
  • Pipe connections / Additional flow above 15 m (g/m) 38 (L-15)
  • Maximum level difference / outdoor unit above indoor unit (m) 20
  • Maximum level difference / outdoor unit below indoor unit (m) 20
  • Supply lines: outdoor unit (number x mm ²) 5 × 2.5
  • Control cables: indoor-indoor unit (Nr. x mm²) 2 × 0.75 (shielded)
  • Fixing spacing (SxG) (mm) 660×462
  • Sound pressure level (dB(A)) 54
  • Sound power level (dB(A)) 66
  • Net dimensions (LxWxH) (mm) 1010x410x850
  • Gross dimensions (LxWxH) (mm) 1165x530x970
  • Net weight / Gross weight (kg) 90 / 104
  • Outdoor operation range / (cooling / heating) (°C) -5~43 / -25~35
  • Outdoor operation range / (DHW) (°C) -25~43
  • Generation X
More Information
ManufacturerRotenso
Weight104.000000
Warranty5
Power kW14.00 kW
Number of Phase3-phase
RefrigerantsR32
Width117.00 cm
Height97.00 cm
Length/Depth53.00 cm