Growatt MOD 10KTL3-XH BACK UP AFCI Inverter 10kW 3PH 2MPPT is available to buy in increments of 1

GROWATT MOD10KTL3-XH Backup Inverter with Emergency Power Function

Advantages:
Ability to operate as a Backup system
Dual MPP trackers
Class II DC and AC surge protection
Active arc fault protection
AFCI (Arc Fault Circuit Interrupter) protection
24-hour self-consumption analysis
Compatibility with APX and ARK batteries
IP66 protection level
Operating temperature range from -25°C to +60°C
Touchscreen display + OLED
10-year basic warranty

Technical Parameters
Dimensions: 425x387x178 mm
Weight: 14 kg
Relative Humidity: 0-100%
Operating Temperature Range: -25°C to 60°C
Standby Power Consumption: < 5.5 W
Protection Level: IP66

DC Input
Maximum PV Power: 20000 W
Maximum DC Voltage: 1100 V
Initial Voltage: 160 V
MPPT Voltage Range: 140 V - 1000 V
Number of PV Strings on a Single MPP Tracker: 2/1
Maximum Input Current per MPP Tracker: 16 A
Maximum Short Circuit Current per MPP Tracker: 20 A

AC Output
AC Rated Power: 10000 W
AC Apparent Power: 11000 VA*
AC Nominal Voltage (Range*): 220 V/380 V, 230 V/400V (340-440V)
AC Grid Frequency (Range*): 50/60 Hz (45-55 Hz/55-65 Hz)
Maximum Output Current: 16.7 A
THDi: < 3%
AC Grid Connection Type: 3-phase (3W+N+PE)
Adjustable Power Factor: 0.8 leading...0.8 lagging

Backup Output Data*
Maximum Apparent Power: 10000 VA
AC Nominal Voltage: 230 V / 400 V
AC Grid Frequency: 50 / 60 Hz

Efficiency
Maximum Efficiency: 98.6%
European Efficiency: 98.1%
MPPT Efficiency: 99.9%

Protections
Reverse Polarity Protection: YES
DC Disconnect: YES
DC Surge Protection: Class II
AC Surge Protection: Class II
Short Circuit Protection: YES
Ground Fault Monitoring: YES
Grid Parameter Monitoring: YES
Leakage Current Break Monitoring: YES
AFCI Protection: YES
String Fault Detection: YES
Differential Current Monitoring Unit: YES

Warranty: 10 years

*The backup function is available for a special version with Backup by using the SYN 50-XH-30 device and the Growatt APX battery system.
*AC voltage range and frequency range may vary depending on the country's grid standard. All data is subject to change without notice.

More Information
ManufacturerGrowatt
Weight15.000000
Number of Phase3-phase
Power kW10.00 kW
Number of MPPT2
Start Voltage160.00 V
Max Input Current16.70 A
Max DC Voltage1,100.00 V
Warranty10