Solar Distribution Box AC 3PH B25 SPD T2

Pre-Order
SKU
1827
The boxes are designed for use in photovoltaic installations with or without insulated lightning protection, also where a high IP degree of protection is required. Their design is suitable for surface mounting

The price includes a complete AC box for self-assembly:

  • 1 x type 2 AC surge arrester
  • 1 x 3-phase overcurrent circuit breaker 25A
  • Ready to connect
  • Modular design
  • Degree of protection IP65
  • Transparent door
  • Protection class II
  • Colour: white

ELECTRICAL AND MECHANICAL CHARACTERISTICS OF THE ENCLOSURE

  • Model PHS 8T
  • Number of modules 8
  • Design in compliance with EN 60670-1, EN 62208
  • Degree of protection IP65
  • Protection class II
  • Rated insulation voltage (Ui) 690 V AC, 1000 V DC
  • 650°C glow rod test
  • Impact resistance IK08
  • Halogen-free recyclable plastic

OVERCURRENT CIRCUIT BREAKER USED

  • Manufacturer/model Noark/Ex9BN 3P B25
  • Rated current 25A; 3-phase
  • Number of poles 3
  • Characteristic B
  • Version according to IEC/EN 60898-1
  • Rated short-circuit breaking capacity ICN 6kA

AC SURGE ARRESTER USED

  • Manufacturer/model Noark/Ex9UE2 12.5 3PN 275
  • Design in accordance with EN 61643-11
  • Arrester type Type 2 (Class II, C, T2)
  • Insertion type L-N: MOV (varistor), N-PE: GDT (spark gap)
  • Endurance voltage Uc L-N: 275 V AC, N-PE: 255 V AC
  • Frequency f 50-60Hz
  • Rated discharge current In (8/20 us) L-N: 20 kA per pole, N-PE: 40 kA per pole
  • Max. impulse current limp (10/350 us) N-PE: 12 kA per pole
  • Max. discharge current Imax (8/20 us) 40 kA per pole
  • Voltage protection level Up for current In L-N: 1,4 kV, N-PE: 1.5 kV
  • Voltage protection level Up for current Imax L-N: 2 kV, N-PE: 1.5 kV
  • Voltage protection level Up for 5 kA (8/20 us) L-N: 2 kV, N-PE: 1.5 kV
  • N-PR fault current suppression capability Ifi 100A
  • Surge surges Ut (withstand) L-N: 5s : 335 V, N-PE: 200 ms : 1200 V
  • Arrester voltage for 1 mA current 387 - 473 V
  • Maximum fuse protection L-N: max. 125 A gG, N-PE: -
  • Short-circuit current withstand capability L-N: 50 kA, N-PE: -
More Information
EAN4127481103399
ManufacturerecoABM
Weight2.380000
VoltageAC
Number of phase3-phase
SPD TypesT2
Width In Number Of Modular Spacings12.00
IP CodeIP65
Width33.00 cm
Height30.00 cm
Length/Depth16.00 cm
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
More from ecoABM
  1. Hanger Bolt M10x300 A2 EPDM
    Hanger Bolt M10x300 A2 EPDM
  2. Hanger Bolt M10x250 A2 EPDM
    Hanger Bolt M10x250 A2 EPDM
  3. Hanger Bolt M10x200 A2 EPDM
    Hanger Bolt M10x200 A2 EPDM
Copyright © 1992-present ecoABM sp. z o.o. All rights reserved.