The boxes are designed for use in photovoltaic installations with or without insulated lightning protection, also where a high IP degree of protection is required. Their design is suitable for surface mounting.
Price includes complete AC box for self-assembly:
- 1 x AC surge arrester type 1+2
- 1 x 3-phase overcurrent circuit breaker 25A
- Ready to connect
- Modular design
- Degree of protection IP65
- Transparent door
- Protection class II
- Colour: white
ELECTRICAL AND MECHANICAL SPECIFICATIONS OF THE ENCLOSURE
- Model PHS 12T
- Number of modules 12
- Design in compliance with EN 60670-1, EN 62208
- Degree of protection IP65
- Protection class II
- Rated insulation voltage (Ui) 690 V AC, 1000 V DC
- 650°C glow rod test
- Impact resistance IK08
- Halogen-free recyclable plastic
OVERCURRENT CIRCUIT BREAKER USED
- Manufacturer/model Noark/Ex9BN 3P B25
- Rated current 25A; 3-phase
- Number of poles 3
- Characteristics B
- Version according to IEC/EN 60898-1
- Rated short-circuit breaking capacity ICN 6kA
AC SURGE ARRESTER USED
- Manufacturer/model Phoenix VAL-MS-T1/T2 335/12.5/3+1
- Design in accordance with EN 61643-11
- Arrester type Type 1 + Type 2
- Rated voltage UN 240/415 V AC (TN-S)
- 240/415 V AC (TT)
- Rated frequency fN 50 Hz (60 Hz)
- Highest operational voltage UC (L-N) 335 V AC
- Highest continuous voltage UC (L-PE) 335 V AC
- Maximum operating voltage UC (N-PE) 264 V AC
- Rated load current IL 80 A
- Protective conductor current IPE <= 5 uA
- Standby power consumption PC <= 810 mVA
- Rated Dissipation Current In (8/20) µs (L-N) 12.5 kA
- Rated Dissipation Current In (8/20) µs (L-PE) 12.5 kA
- Rated Dissipation Current In (8/20) µs (N-PE) 50 kA
- Max. discharge current Imax (8/20) us 50 kA
- Test lightning current (10/350) µs (L-N), charging 6.25 As
- Test lightning current (10/350) µs (L-N), specific energy 39 kJ/ohm
- Test lightning current (10/350) µs, (L-N) peak current Iimp12,5 kA
- Test lightning current (10/350) µs (L-PE), charge 6,25 As
- Test lightning current (10/350) µs (L-PE), specific energy 39 kJ/ohm
- Test lightning current (10/350) µs, (L-PE) peak current Iimp 12,5 kA
- Test lightning current (10/350) µs (N-PE), charge 25 As
- Test lightning current (10/350) µs (N-PE), specific energy
- Total dissipated current Itotal (8/20) µs 50 kA
- Total dissipated current Itotal (10/350) µs 50 kA
- 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA
- Short-circuit withstand capability ISCCR 25 kA
- Protection level Up (L-N) <= 1,2 kV
- <= 1,6 kV (30 kA - 8/20 us)
- UP (L-PE) protection level <= 2 kV
- Protection level UP (N-PE) <= 1,7 kV
- Residual voltage Ures (L-N) <= 1,2 kV (at In)
- <= 1,1 kV (at 10 kA)
- <= 1 kV (at 5 kA)
- <= 0.9 kV (at 3 kA)
- Residual voltage Ures (L-PE) <= 2 kV (at In)
- <= 1.5 kV (at 10 kA)
- <= 1,2 kV (at 5 kA)
- <= 1.1 kV (at 3 kA)
- Residual voltage Ures (N-PE) <= 0.6 kV (at In)
- <= 0.5 kV (at 10 kA)
- <= 0,5 kV (at 5 kA)
- <= 0,4 kV (at 3 kA)
- TOV behaviour for UT (L-N) 415 V AC (5 s / withstand mode)
- 457 V AC (120 min / safe failure mode)
- TOV behaviour for UT (N-PE) 1200 V AC (200 ms / withstand mode)
- Tripping time tA (L-N) <= 25 ns
- tripping time tA (L-PE) <= 100 ns
- tripping time tA (N-PE) <= 100 ns
- Maximum primary fuse in through installations V 80 A (gG - 16 mm2)
- Maximum fuse value in radial installations 160 A (gG)
EAN | 4129678027259 |
---|---|
Manufacturer | ecoABM |
Weight | 2.560000 |
Voltage | AC |
Number of phase | 3-phase |
SPD Types | T1+T2 |
Width In Number Of Modular Spacings | 12.00 |
IP Code | IP65 |
Width | 33.00 cm |
Height | 30.00 cm |
Length/Depth | 16.00 cm |