HOYMILES HMS-2000-4T Microinverter 2kW 1PH

HOYMILES HMS-2000-4T Microinverter 2kW 1PH is available to buy in increments of 1

HOYMILES Microinverter HMS-2000-4T

The 2000 VA output power places the new Hoymiles microinverter series - HMS-2000 - among the leading 4-in-1 microinverters.
Each microinverter can connect up to 4 panels with independent MPPT and monitoring to maximize PV production in the installation.
The new solution based on sub-1 GHz wireless network enables more stable communication with the Hoymiles DTU gateway.

Features:
High-power microinverter with an output power of up to 2000 VA
Independent MPPT and monitoring for increased energy harvesting and easier maintenance
Reactive power controller compliant with EN 50549-1:2019, VDE-AR-N 4105:2018, VFR2019, etc.
4-in-1 design allows for fast installation and lower costs
Enhanced safety for rooftop photovoltaic stations with compliance to rapid shutdown and galvanic isolation transformer standards
Wireless network-based solution in the sub-1 GHz band enables stable communication in commercial and industrial environments

Technical data:

Model: HMS-2000-4T

Input data (DC):

Power of commonly used modules (W): 400 to 670+
Maximum input voltage (V): 65
MPPT voltage range (V): 16–60
Startup voltage (V): 22
Maximum input current (A): 4 x 16
Maximum input short-circuit current (A): 4 x 25
Number of MPPTs: 4
Number of inputs per MPPT: 1

Output data (AC):
Rated output power (VA): 2000
Rated output current (A): 9.09 / 8.7 / 8.33
Nominal output voltage (V): 220/180–275 -- 230/180–275 -- 240/180–275
Nominal frequency/range (Hz)*: 50/45–55 or 60/55–65
Power factor (adjustable): >0.99 default 0.8 (leading)...0.8 (lagging)
Total harmonic distortion: <3%
Maximum number of units per branch 10AWG2: 3 / 3 / 3

Efficiency:
Peak efficiency CEC: 96.50%
MPPT rated efficiency: 99.80%
Night power consumption (mW): <50
Mechanical data:
Ambient temperature range (°C): -40 to +65
Dimensions (width × height × depth mm): 331 × 218 × 36.6
Weight (kg): 4.7
Enclosure protection class: External NEMA 6 (IP67)
Cooling: Natural convection (fanless)

Features:
Communication: Sub-1G
Isolation type: Galvanically isolated HF transformer
Monitoring: Hoymiles S-Miles Cloud
Compliance: EN 50549-1:2019, VDE-AR-N 4105:2018, VFR2019, IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4, IEC/EN 61000-3-2/-3

*1 The range of nominal voltage/frequency depends on local requirements.
*2 The exact number of microinverters per branch should comply with local requirements.
*3 Hoymiles Monitoring Platform

More Information
Manufacturer Hoymiles
Weight 4.700000
Width 21.80 cm
Height 33.10 cm
Length/Depth 3.70 cm
Number of Phase 1-phase
Power kW 2.00 kW
Number of MPPT 4
Start Voltage 22.00 V
Max Input Current 16.00 A
Max DC Voltage 65.00 V
Warranty 12